Prev Next
The LLC_DLC_PARMS structure represents the DLC parameter table for the
LLC_DIR_OPEN_ADAPTER command. You pass a pointer to this structure in the LLC_DIR_OPEN_ADAPTER_PARMS
structure.
typedef struct {
UCHAR uchDlcMaxSaps;
UCHAR uchDlcMaxStations;
UCHAR uchDlcMaxGroupSaps;
UCHAR uchDlcMaxGroupMembers;
UCHAR uchT1_TickOne;
UCHAR uchT2_TickOne;
UCHAR uchTi_TickOne;
UCHAR uchT1_TickTwo;
UCHAR uchT2_TickTwo;
UCHAR uchTi_TickTwo;
} LLC_DLC_PARMS, *PLLC_DLC_PARMS;
Members
-
uchDlcMaxSaps
-
The maximum number of SAPs that can be opened at one time. This value can be
limited by available memory. Specify up to 126. If the value is zero, as the
default setting of 2 is used.
-
uchDlcMaxStations
-
The maximum number of link stations that can be opened at one time. This value
can be limited by available memory. Specify up to 255. If the value is zero,
the default setting of 6 is used.
-
uchDlcMaxGroupSaps
-
The maximum number of group SAPs that can be opened at one time. Specify up to
125. If the value is zero, no group SAPs are allowed.
-
uchDlcMaxGroupMembers
-
The maximum number of SAPs that can be assigned to any given group. Specify up
to 126.
-
uchT1_TickOne
-
The number of 40 millisecond intervals between timer ticks for the short DLC
timer T1 (T1 timer values 1 through 5). If the value is zero, the default
setting of 5 is used.
-
uchT2_TickOne
-
The number of 40 millisecond intervals between timer ticks for the short DLC
timer T2 (T2 timer values 1 through 5). If the value is zero, the default
setting of 1 is used.
-
uchTi_TickOne
-
The number of 40 millisecond intervals between timer ticks for the short DLC
timer Ti (Ti timer values 1 through 5). If the value is zero, the default
setting of 25 is used.
-
uchT1_TickTwo
-
The number of 40 millisecond intervals between timer ticks for the long DLC
timer T1 (T1 timer values 6 through 10). If the value is zero, the default
setting of 25 is used.
-
uchT2_TickTwo
-
The number of 40 millisecond intervals between timer ticks for the long DLC
timer T2 (T2 timer values 6 through 10). If the value is zero, the default
setting of 10 is used.
-
uchTi_TickTwo
-
The number of 40 millisecond intervals between timer ticks for the long DLC
timer Ti (Ti timer values 6 through 10). If the value is zero, the default
setting of 125 is used.
See Also
AcsLan, LLC_DIR_OPEN_ADAPTER_PARMS
file: /Techref/os/win/api/win32/struc/src/str09_49.htm, 3KB, , updated: 2000/4/7 11:20, local time: 2024/11/27 09:39,
|
| ©2024 These pages are served without commercial sponsorship. (No popup ads, etc...).Bandwidth abuse increases hosting cost forcing sponsorship or shutdown. This server aggressively defends against automated copying for any reason including offline viewing, duplication, etc... Please respect this requirement and DO NOT RIP THIS SITE. Questions? <A HREF="http://sxlist.com/techref/os/win/api/win32/struc/src/str09_49.htm"> LLC_DLC_PARMS</A> |
Did you find what you needed?
|
.