FUSEX Word

(Read/Program via Programming Command)

After the chip enters the ISP mode, the address is pointing to the FUSE word and the FUSE word location can be accessed only once. Programming the FUSE word after incrementing the address 4096 times doesn't seem work. If it is programed it before incrementing the address, it works fine.

For the SX18-28:

bit 11,9,8: IRCTRIM2:IRCTRIM0

Internal RC oscillator trim bits. This 3-bit field adjusts the operation of the internal RC oscillator to make it operate within the target frequency range 4 MHz plus or minus 8%. Parts are shipped from the factory untrimmed. The device relies on the programming toll to provide the trimming function. Each step is about 3%

bit 10: PINS

bit 7: OPTIONX/STACKX

OPTION Register Extension and Stack Extension. Set to 1 to disable the programmability of bit 6 and bit 7 in the OPTION register, the RTW and RTE_IE bits (in other words, to force these two bits to 1) and to limit the program stack size to two locations. Clear to 0 to enable programming of the RTW and RTE_IE bits in the OPTION register, and to extend the stack size to eight locations.

bit 6: CF ( CARRYX )

Active low – makes carry bit input to ADD and SUB instructions. Note that JMP PC+xx and CJE each have an add or subtract instruction included and so are affected by the carry bit.

bit 5,4: BOR1: BOR0

Brown-Out Reset;These bits enable or disable the brown-out reset function and set the brown-out threshold voltage as follows:

bit 3,2: BORTRIM1:BORTRIM0

Brown-Out trim bits (parts are shipped out of factory untrimmed).

bit 1,0: PB1:BP0

Configure Memory Size:


bit 7: BOSC

Remove “Banks” column from:

MEM1:MEM0 Configured memory size on chip

See:


file: /Techref/scenix/fuse.htm, 3KB, , updated: 2004/4/5 17:33, local time: 2024/11/22 19:44,
TOP NEW HELP FIND: 
3.137.219.68:LOG IN

 ©2024 These pages are served without commercial sponsorship. (No popup ads, etc...).Bandwidth abuse increases hosting cost forcing sponsorship or shutdown. This server aggressively defends against automated copying for any reason including offline viewing, duplication, etc... Please respect this requirement and DO NOT RIP THIS SITE. Questions?
Please DO link to this page! Digg it! / MAKE!

<A HREF="http://sxlist.com/Techref/scenix/fuse.htm"> FUSEX Word</A>

After you find an appropriate page, you are invited to your to this massmind site! (posts will be visible only to you before review) Just type a nice message (short messages are blocked as spam) in the box and press the Post button. (HTML welcomed, but not the <A tag: Instead, use the link box to link to another page. A tutorial is available Members can login to post directly, become page editors, and be credited for their posts.


Link? Put it here: 
if you want a response, please enter your email address: 
Attn spammers: All posts are reviewed before being made visible to anyone other than the poster.
Did you find what you needed?

 

Welcome to sxlist.com!


Site supported by
sales, advertizing,
& kind contributors
just like you!

Please don't rip/copy
(here's why

Copies of the site on CD
are available at minimal cost.
 

Welcome to sxlist.com!

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  .