Our system is 18, 175 watt, Sharp panels with inverter. Purchased from: http://www.heliopower.com After some delay due to poor weather, the instalation was absolutly clean and smooth. Not one flower was broken in the beds around the house, not one bit of trash was left behind. The crew was polite and respectful and did not disturb my family in any way. Helio Power has my highest recommendation, at least as of 2004.
Costs: $21,000 base price less CEC Rebate @ $2.80/W ($7,305) less CA state tax credit @ 7.5% ($1,035) leaves $12,759 total out of pocket.
Cash Flow: Assuming an average utility tariff of $0.17 (conservative) we should see a savings of at least $1,000/year so the worst case payback is in 12 years. Since the purchase price went on a home equity loan at 6%, over 25 years the payment will be about $82/month or a cost of $986.52/year. If energy prices continue to soar and the economy is weakened as a result, interest rates will stay low and my cash flow will continue to improve. Of course, if electricity rates fall, and interest rates soar... but that seems very unlikely at this point.
R.O.I.: Since the system increases the sale value of the home by an estimated $17,493, We've increased our net worth almost $5,000 instantly. Since we could potentially sell the system for about $10,000 (value of the used system) our exposure is only $2,000 or about 2 years of the power bills. Since the panels are warrentied for 25 years, they will not decrease in value by any significant amount so payback should be in just over 2 years at worst. After that, part of each loan payment will increase net worth rather than the net worth of the local utility.
The first power bill after the system was installed was $29 for Natural Gas. Zero electic use. That is in April, in SoCal, so it should represent a solid average for the year.
After 1 year, the system has generated 5,000 Killowatt/hours = 13.7 kWh/day or about $1,400 worth of power over this years rates (if I am calculating the rates correctly). And that is with one set of pine trees from our neighbor's front lawn that were shading half the panels every morning. Those pines are gone now (the wood will heat our home next year, the chippings are mulch for our trees and garden). The variable interest rate on the equity loan is up to 9 percent, so we are paying about $104 per month or $1,248 per year. That leaves a net positive cash flow of $152 for the year.
The left hand set of panels. The smoke stack for our wood stove is visable to the right. |
The right hand panels. The controller is in the lower left corner of the picture and the electrical conduit from the panels to the control can be seen comming down from the roof. |
The controller / inverter and it's connection to the power grid. Not shown is the standard power meter, which does run backwards during the day. |
Here is a rough sketch of the roof and panels which I intend to use to create a computer model for simulation of mirror systems:
roof1.tif (52KB) roof2.tif (10KB)
See also:
See also:
As of April 27, 2008, the system has generated 14,831 Kilowatt Hrs. or about 4943KWH/year. +
As of April 20 2009, the system has generated 19,241 Kilowatt Hrs, 4410HKW since last year +
As of April 19, 2010, the system had generated 23,663 Kilowatt Hrs, 4422KWH since last year. +
As of April 20, 2011, the system had generated 28,503 Kilowatt Hrs, 4840KHW since last year.
As of April 19, 2012, the system had generated 33,108 Kilowatt Hrs, 4650KHW since last year.
As of April 19, 2013, the system had generated 37,583 Kilowatt Hrs, 4475KHW since last year. +
On August 5th, 2013, the Xantrex inverter failed. The 5 year warranty on the unit was long expired, so replacement cost $2,205.84 (by Heliopower, labor included). The new "Sunny Boy" SB-3000US unit has a connector for an optional RS-485 or Webconnect module and a 10 year warranty. With a 20 year warranty on our Sharp panels (10 years remaining), and about $1000 saving in electricity per year, we should have the system paid for (again) by January 2016 and get about 7 years of free electricity under warranty. +
As of August 2014, the new inverter had produced 4,207 Kilowatt Hrs. +
On May 2nd, 2015 at 7pm the new inverter is showing all three lights on and no text on the display. Manual indicates this is a ground fault. Disconnected from AC, called and left a message at 951.677.7755 and sent a message via the email form on heliopower.com. +
It turns out that this is perfectly normal. The manual indicates that the yellow and red leds being on is a ground fault and fails to mention that all is well if the green light is also on. After re-connecting to AC, all is well, meter turning backwards again. Thanks to HelioPower for setting me right. +
As of August 2016, the new inverter had produced 13,931 Kilowatt Hrs. 4724 since last year. +
As of August 2017, the new system is at 18,236 KWH or 4305 since last year +
As of August 2018, the new system is at 22,327 KWH or 4091 since last year +
2019/04/02 to 05/20 PV system down to replace roof. +
2019/06/01 Added a 1.2 KW "micro" system with 5 panels each with their own Enphase IQ6 Microinverter. System is now a 5.2 KWp system. Monitoring is now available at
https://www.sunnyplaces.com/app/energyChart?userId=80efe6a2-170a-4b32-adba-4c9db57c9d56&plantId=f652f918-1671-4a4b-a29f-3938c3452384
+
file: /Techref/other/solar/case1.htm, 10KB, , updated: 2020/3/31 13:05, local time: 2024/11/26 08:56,
18.118.144.98:LOG IN
|
©2024 These pages are served without commercial sponsorship. (No popup ads, etc...).Bandwidth abuse increases hosting cost forcing sponsorship or shutdown. This server aggressively defends against automated copying for any reason including offline viewing, duplication, etc... Please respect this requirement and DO NOT RIP THIS SITE. Questions? <A HREF="http://sxlist.com/Techref/other/solar/case1.htm"> Our Solar Electric Panels</A> |
Did you find what you needed? |
Welcome to sxlist.com!sales, advertizing, & kind contributors just like you! Please don't rip/copy (here's why Copies of the site on CD are available at minimal cost. |
Welcome to sxlist.com! |
.